Increasing the Reliability of Distribution Systems By Utilizing Mobile Transformer Units

Authors

  • Abdul Multi Institut Sains dan Teknologi Nasional, Jakarta, Indonesia
  • Muhammad Rijal Cahyadi Institut Sains dan Teknologi Nasional, Jakarta, Indonesia

DOI:

https://doi.org/10.38035/ijam.v4i1.804

Keywords:

Transformer Maintenance, Outage Duration, Reliability, SAIDI, ENS

Abstract

Maintenance of electrical installations continues to be carried out in maintaining reliability of continuity of electricity distribution. Distribution transformer maintenance activities are carried out in a state without voltage. Of course, with condition without voltage, it has an impact on power outages which can reduce reliability value of the distribution system. In 2024, PT PLN (Persero) UP3 Cempaka Putih has carried out transformer maintenance activities at 7 distribution substations with an average outage duration is 155 minutes. At Distributon Substation TP117, transformer maintenance has been carried out using a minimal outage method, namely by utilizing Mobile Transformer Units as mediator for temporary load transfer during maintenance. Total duration of the outage was only 44 minutes with value of SAIDI is 0.035 minutes/customer and value of ENS is 245,084.07 Wh. By calculating the SAIDI and ENS values based on the pure duration of maintenance work, SAIDI value is calculated to be greater, amount 0.102 minutes/customer and the ENS value is 708,515.77 Wh. So it can be determined that the potential reduction for SAIDI value is 65.69% and ENS value is 65.41%. This means that the reliability of the distribution system can increase because the SAIDI and ENS values can be reduced.

References

Berahim, Hamzah. (1996). Pengantar Teknik Tenaga Listrik Teori Ringkas dan Penyelesaian Soal (Second Edition). Yogyakarta: ANDI OFFSET.

Brush, Kate. (2024). Standard Operating Procedure (SOP). https://www.techtarget.com/ searchbusinessanalytics/definition/standard-ope rating-procedure-SOP

Chowdhury, Ali A, & Koval, Don O. (2009). Power Distribution System Reliability, New Jersey: John Wiley & Sons, Inc

Gonen, Turan. (1986). Electric Power Distribution System Engineering, New York: McGrawHill Book Company

Gumilang, Adibtyo Putro & Wibowo, Rony Seto & Negara, I Made Yulistya. (2018). Penilaian Keandalan Sistem Tenaga Listrik Jawa Bagian Timur Dan Bali Menggunakan Formula Analitis Deduksi Dan Sensitivitas Analitis Dari Expected Energy Not Served. Jurnal Teknik Elektro Institut Teknologi Sepuluh Nopember

Harahap, R. & Farizi, Hasbie & Kasim, Surya Tarmizi & HS, Syafruddin. Analisis Indeks Keandalan Pada Jaringan Distribusi 20 kV Penyulang KA.1, KU.1 Dan TW.1 Di PT PLN (Persero) UP3 Lubuk Pakam. Jurnal Teknik Elektro Universitas Sumatera Utara

Kelompok Kerja Standar Kontruksi Jaringan Disribusi Tenaga Listrik dan Pusat Penelitian Sains dan Teknologi Universitas Indonesia. (2010). Buku 1 : Kriteria Desain Enjiniring Konstruksi Jaringan Distribusi Tenaga Listrik, Jakarta: PT PLN (Persero)

Kelompok Kerja Standar Kontruksi Jaringan Disribusi Tenaga Listrik dan Pusat Penelitian Sains dan Teknologi Universitas Indonesia. (2010). Buku 4 : Standar Konstruksi Gardu Distribusi dan Gardu Hubung Tenaga Listrik, Jakarta: PT PLN (Persero)

Kurniawan, Hendro Tri & Sirait, Bonar & Junaidi. (2014). Evaluasi Keandalan Sistem Jaringan Distribusi Menggunakan Indeks SAIDI Dan SAIFI Pada PT PLN (Persero) Area Pontianak. Jurnal Teknik Elektro Universitas Tanjungpura

Markoni. (2014). Teori Dasar Tenaga Listrik, Jakarta: Graha Ilmu

Maulana, Achmad Dhyta & Fatkhurrokhman, Mohammad. (2023). Analisis Perawatan dan Penanganan Pada Trafo Distribusi 20 kV di PT Krakatau Tirta Industri (Water Solution). Jurnal Teknik Elektro Universitas Sultan Ageng Tirtayasa

Mubarrok, Muhammad Sayfik & Yannuansa, Nanndo. (2022). Perawatan Tansformator Distribusi Untuk Menjaga Keandalan Sistem Distribusi Jaringan Listrik. Jurnal Teknik Elektro Universitas Hasyim Asy’ari

Nurhadi, Slamet & Mieftah, Mochammad & Sungkowo, Heri & Sukamdi. (2024). Peningkatan Keandalan Berbasis Nilai Energy Not Supplied (ENS) Pada Penyulang Banyu Biru. Jurnal Teknik Elektro Politeknik Negeri Malang

Pooler, W.J.R.H. (2011). Electrical Power. Colorado: Ventus Publishing

Randa, Ya M. & Hardiansyah & Purwoharjono. (2020). Evaluasi Keandalan Sistem Jaringan Distribusi 20 kV Dan Rugi-Rugi Energi Yang Tidak Tersalurkan Pada Feeder Raya 10/Adisucipto. Jurnal Teknik Elektro Universitas Tanjungpura

Rosyidi, Nizar & Purnama, Deki. (2021). Pengujian Tegangan Tembus Pada Minyak Trafo. Jurnal Teknik Elektro Institut Sains dan Teknologi Nasional

Sarimun, Wahyudi. (2014). Buku Saku Pelayanan Teknik. Depok: Garamond

Syukri & Muliadi & Setiawan, Toni. (2022). Kajian Pemeliharaan Trafo Distribusi Menggunakan Metode Codition Based Maintenance (CBM). Jurnal Teknik Elektro Universitas Iskandarmuda

Teknik Pemeliharaan Transformator. Jakarta: PT PLN (Persero) Pusat Pendidikan dan Pelatihan

Teori Transformator. Jakarta: PT PLN (Persero) Pusat Pendidikan dan Pelatihan

Transformer Windings: Types and Design. (2022). https://studyelectrical.com/2022/11/ transformer-windings-types-and-design

Uppal, S.L. (1979). Electrical Power. Delhi: Khanna Publishers

Weedy, B.M. & Cory, B.J. & Jenkins, N. & Ekanayake, J.B & Strbac, G. (2012). Electric Power Systems (Fifth Edition). West Sussex: John Wiley & Sons Ltd

Wisnu Sri Nugroho. (2017). Mengenal Sistem Tenaga Listrik. https://catatanwsn.wordpress. com/2017/11/11/mengenal-sistem-tenaga-listrik/

Published

2025-04-30

How to Cite

Multi, A., & Cahyadi, M. R. (2025). Increasing the Reliability of Distribution Systems By Utilizing Mobile Transformer Units. International Journal of Advanced Multidisciplinary, 4(1), 77–87. https://doi.org/10.38035/ijam.v4i1.804