Calculation Analysis of Wire Feeder Power Delivery Efficiency on LineX – Y, Middle Java

Authors

  • Edy Supriyadi Institut Sains Dan Teknologi Nasional, Jakarta, Indonesia
  • Iriandi Ilyas Institut Sains Dan Teknologi Nasional, Jakarta, Indonesia
  • Ariman Institut Sains Dan Teknologi Nasional, Jakarta, Indonesia
  • Raihan Shodiq Institut Sains Dan Teknologi Nasional, Jakarta, Indonesia

DOI:

https://doi.org/10.38035/ijam.v2i3.425

Keywords:

Traction Substation, KRL, Overflow Network, Feeder Wire, Electrical resistivity

Abstract

The electric train (KRL) is a form of application of scientific and technological developments in the field of transportation so that KRL can replace modes of transportation that use coal or use diesel. Currently electric trains in Indonesia are one of the modes of transportation that are most widely used every day for activities ranging from transportation for schools and colleges to transportation used to go to work and other important activities. Every year electric train passengers in Indonesia are increasing, starting from 100 thousand passengers per day until it is predicted to be 1 million passengers per day. The capacity of the Purwosari Traction Substation (GT) can be categorized as sufficient, with the difference between the specifications of the power capacity and the calculated capacity of only 57.9%. On the Purwosari – Solo Balapan route, the cable type resistance was 0.000167 ?/m, from this type of resistance to the resistance calculated from usage, a difference of around 20.9%. As for the Feeder Wire type resistance, the cable specification limit with the calculation is still below the maximum limit so it is still feasible to use. Because the specification limit and the calculation results are around 99.654% of the limit at 20°C.

References

Dugan, Roger. C and Mc Granaghan, Mark.F. Electrical Power System Quality (2003). New York: McGraw-Hill, pp 93-120, 2003.

Marlock, E. K. (1985). Introduction to Transportation Engineering and Planning , Jakarta: Erlangga.

Rahadian Fikri, Andri. (2013). Maintenance of the Upflow Electricity Network System at PT KAI. Laporan Kerja Praktik Kerja Lapangan Teknik Elektro Politeknik Negeri Jakarta.

F. W. Kurniawan (2020), "Simple Catenary Type Upstream Electricity in PPI-Madiun Campus Area,"pp. 23–24, 2020.

Ida Widihastuti, Dedi Nugroho (2020), " Voltage Drop Analysis on Feeder K3 Kudus Substation ", Laporan Penelitian Program Studi Teknik Elektro Universitas Islam Sultan Agung Semarang.

Directorate of Railway Infrastructure Monitoring Report on Performance Outcomes for the Third Quarter of 2021.

Published

2023-12-20

How to Cite

Supriyadi, E., Iriandi Ilyas, Ariman, & Raihan Shodiq. (2023). Calculation Analysis of Wire Feeder Power Delivery Efficiency on LineX – Y, Middle Java. International Journal of Advanced Multidisciplinary, 2(3), 800–808. https://doi.org/10.38035/ijam.v2i3.425